Ankersmid heated lines series AHLX2003-PAAHLX2003

For high temperatures

up to 200°C

 

Fixed PTFE-tube

(6x1, 8x1 or 10x1 mm)

 

ATEX-APPROVED

 

Application

This electrical heated AHLX2003-PA sample tube is designed to transport sample gas through an explosive zone type 1 op 2, but not zones type 0. They can be connected to all Ankersmid sample elements. They are used to keep the necessary gas components above their ACID-dew point, and avoid condensation.

This is a safe way to transport the sample to a heated analyser or the special Ankersmid coolers.

 

Description

Fixed sample tube out of PTFE in a second PTFE-tube.

These AHLH2004-PA heated lines are manufactured according to the clients needs and completely confectioned in the factory at a fixed length.

The sample line is standard equipped with a PT100 for temperature control. The heater used in this type is ONE serial resistance, twisted around the tube. Due to this construction we can not have cold zones or spots, where a potential blockage can occur.

Flexible isolation out of multi-layer glass wool.

A variety of standard lines is available but many options can be supplied as well.

Ready-to-use with multi-pole connector.

This heated sample tube is ready-to-use on each tip a stainless steel stud makes connection easy.

 

See our code page Chpt. 2.1.1 for all versions.

 

·               Completely manufactured “ready-to-use”

·               Never cold spots

·               Tube 6x1 , 8x1 or 10x1 mm

·               PTFE-tube fixed

·               Max. available length 48 meter

·               One serial heater with PTFE-insulation and protective gain of stainless steel

·               2 sensors PT100 are incorporated at 300 mm from the tip of the line

·               The electric cables are 1,5 meter, only to be used with ATEX-approved temperature controller and limiter

·               CE-certified under no. EX5 07 10 29587 004

 

 

Schematic picture

 

 

Free wires

 

 

L        Total length

DA      Outside diameter of inner tube

DK      Silicon end connection outside diameter

DM     Corrugated tube outside diameter

LA      Length of connection stud

LK      Length of silicon end connection

LL       Length of cable connection

 

 

DN

6x1

8x1

10x1

DA

8 mm

10 mm

12 mm

DK

64 mm

DM

54 mm

LA

25 mm

26 mm

LK

110 mm

LD

80 mm

LE

35 mm

Pressure

100 W/m

125 W/m

Total length

48 m

37 m

Max. working pressure

180 bar

160 bar

120 bar

 

Electric cables always manufactured at an angle of 90° (see photo)

 

 

ATEX Definition

 

 

 

 

  • One serial heater 
  • Ready-to-use 
  • CE0123 TUV approval 
  • EX II 2G EEXe ma IIC T3 

 

 

 

 

 

 

 

 

 

  • II      Protected against explosion group II 
  • 2G    category (zone 1) 
  • EEx   European standard 
  • ℮       ensured as per DIN EN 60079-7 
  • ma    ensured as per (moulding) DIN EN 60079-18 
  • IIC   gas group (hydrogen) 
  • T3     temp. class up to 200°C 

 

 

Ankersmid purchase codes (extraction, see code page Chapter 2.1.1 for all available versions)

 

Sample line

version

Power

supply

Outer

diameter

Description

code

Length code x (meter)

Beginning and end fitting (1x)

ATEX-approved

PTFE-tube

Fixed

Max. 200°C

230VAC

6mm

AHLX2003-PA06-230E

AHL094

AHL904

ATEX-approved

PTFE-tube

Fixed

Max. 200°C

230VAC

8mm

AHLX2003-PA08-230E

AHL095

AHL905

ATEX-approved

PTFE-tube

Fixed

Max. 200°C

230VAC

10mm

AHLX2003-PA10-230E

AHL096

AHL906

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example:       AHLX2003-PA06-230E

Coding:

AHL:                      Ankersmid Sampling, Heated Line

X:                ATEX-version

200:             Maximum regulated setpoint 200°C

3:                Fixed PTFE-tube with SS stud

PA:              Outer PA-jacked corrugated and thermal fleece insulation

06:               Outside tube diameter 6mm

230:             Supply 230VAC

E:                PT100 ATEX-version

 

Documentation

General terms of delivery 2024 ENG General terms of delivery 2024 ENG
Algemene leveringsvoorwaarden 2024 Algemene leveringsvoorwaarden 2024
Contaminatie verklaring Contaminatie verklaring

Service

Service and linearity reports for all your analysis Service contracts up to 4 hours on site consignment. 

certification services

Calibrate measuring equipment in accordance with EN 14181. To guarantee the reliability of equipment, we calibrate components in accordance with the EN 14181 guideline regarding Quality Assurance Level 3 (QAL3). 

Products

Our products listed by industry 

Rental

Here you see our current inventory rental analysers. 

Applications

Find regular used applications 

Vacancies

We are looking for a full-time service employee for the field service department 

Brands

Reputable companies that we work closely with. 

News

Our latest products and representments 

About us

View the contact details of a distributor near you!  

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group