Vochtigheidssensor, Litronic-FMS planaire P71-HD met PEEK

Klein, fijn, uitstekend... en nieuw in hygiënisch design.

Onze sensoren in combinatie met het Liebherr vochtmeetsysteem type Litronic-FMS zijn onmisbaar geworden voor vele industriële processen in diverse branches en zijn nu ook ontworpen voor gebruik in hygiënekritische productieomgevingen in de voedingsmiddelenindustrie.

Bepaal het vocht-/watergehalte tijdens diverse voedselproductie-, verwerkings-, raffinage- en monitoringprocessen.

De vochtmeetinstallatie werd in 1985 uitgevonden in de fabriek in Bad Schussenried. De meting door het Liebherr-sensorsysteem is gebaseerd op het natuurkundige principe van capaciteitsbepaling in het hoogfrequente strooiveld.

Kenmerken

  • Vochtsensor - capaciteitsmeting in een hoogfrequent strooiveld
  • Temperatuursensor PEEK-contactoppervlak
  • EHEDG-gecertificeerd TYPE EL, KLASSE I, MEI 2023 1.)
  • FDA-conform
  • Roestvrijstalen behuizing V4A (1.4404) / 316L
  • Geschikt voor SIP/CIP-gebruik
  • VARINLINE® behuizing type N procesaansluiting
  • Geldige regelgeving: EG 1935/2004; (EU) nr. 10/2011
  • GMP (Good Manufacturing Practice) (EU) nr. 2023/2006
  • Gevoeligheid instelbaar in drie niveaus
  • Grenswaardecontrole
  • Geïntegreerde microprocessor met gemiddelde waardecalculator
  • Temperatuurcompensatie
  • Sensorvervanging zonder herkalibratie

 

Planar sensor P71-HD

 

Power supply 8…30V, 0.4 VA
Measuring range 0 – 100 % moisture content (measuring window adjustable)
Max. measuring accuracy +/- 0.05 % moisture content 2.)
Temperature measurement accuracy +/- 0.5 °C
Max. pressure in connection with Varinline® housing flange N 16 bar
Operating ambient temperature +5 – +80 °C
Operating temperature electronics -20 – +80 °C
CIP – max. cleaning temperature
(temperature/duration/ambient temperature)
90 °C / 30 min / 25 °C
SIP – max. sterilization temperature (steam)
(temperature/duration/ambient temperature)
121 °C / 15 min / 25 °C
Update cycle 32.64 ms
Protection class IP65, IP67, IP69K
Wear protection PEEK
Gasket EPDM E7502 3.)
Housing/flange material V4A (1.4404) / 316L
Dimensions: Ø / height 84 mm / 58 mm (without cable gland)
Weight without cable 1.2 kg
Connecting cable length 6 m
Connecting cable type UNITRONIC®ROBUST C 7x0.14 shielded
Measurement value transfer digital: RS-485, multi-processor protocol
Max. number of sensors on bus 16
Max. bus length 1200 m

1.) EHEDG logo may only be used in connection with the following designation “Moisture sensor, Litronic-FMS planar sensor type P71-HD with PEEK product contact surface and EPDM E7502”

2.) Representative according to the batch or the period of continuous operation with the corresponding evaluation unit Litronic-FMS II, depending on material, ideal material flow and proper calibration

3.) EHEDG approved material in connection with the logo

Documentatie

reliable-moisture-measurement-system-litronic-fms reliable-moisture-measurement-system-litronic-fms
ehedg-certificate ehedg-certificate
data-sheet-p71-hd data-sheet-p71-hd
fms-measurement-method-data-sheet fms-measurement-method-data-sheet

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2025 - Ankersmid Group