SM-5 Mercury CEMS

Totale kwikemissiemonitor in rookgassen S5-5 kwik CEMS

De nieuwe SM-5 CEMS Hg-analysator, die meer dan 20 jaar ervaring heeft in het meten van kwik, is ontworpen om uiterst nauwkeurige en betrouwbare continue metingen van zeer lage concentraties Hg in rookgasemissies te leveren.

De SM-5 beschikt over korte responstijden, dynamische bereiken en stabiele metingen onder alle omstandigheden.

QAL1-certificeringsbereik 0-5 µg/m3, de laagste op de markt

KENMERKEN & VOORDELEN
  • Certificatiebereiken: 0-5 : 0-30; 0-45; 0-100; 0-1000 µg/m3
  • Zeer hoge nauwkeurigheid: <0,1 μg/m3 over 3 maanden
  • Dynamisch bereikomschakeling voor betrouwbare meting van kwikemissiepieken
  • Fotometrische meting onafhankelijk van de hogetemperatuuromvormer om zeer lage onderhoudstijden en -kosten te garanderen
  • Conversiemethode bij hoge temperatuur: vereist geen reagens, watervulling of vervanging van cartridges
  • Geen kalibrator nodig om te werken: betrouwbaarheid en lagere bedrijfskosten
  • Modulair kwikinjectiesysteem bij de sonde of bij de analysator voor volledige AMS-controles
  • Sondekoppoort voor optioneel aansluiten van een kalibratiesysteem
  • Geen draaggas, verdunning of airconditioning nodig, zeer laag verbruik van nutsvoorzieningen (geen stikstof vereist)
  • Monsterbox gemonteerd op de stack: geen onderhoud nodig, geen transport van reactief Hg
  • Twee verschillende stroombronnen (beschermd/onbeschermd) om het meetsysteem te scheiden en te beveiligen
  • Automatische terugspoelfunctie
  • Weinig onderhoud en geoptimaliseerde bedrijfskosten
BELANGRIJKSTE TOEPASSINGEN
Hg CEMS-monitor perfect aangepast voor continue kwikanalyse in:
  • Afvalverbrandingsinstallaties (industrieel, medisch, gevaarlijk afval, zuiveringsslib…)
  • Kolencentrales (voor en na kwikabsorbers)
  • Cementovens
  • Bepaling van kwik in fabrieken voor de productie van zwavelzuur
  • Thermische behandeling van verontreinigde gronden, gevaarlijk afval
  • Metallurgische installaties met potentiële Hg-emissies...

TECHNICAL SPECIFICATIONS
QAL1 certification range 0-5 µg/m3
Additional ranges: 0-30; 0-45; 0-100; 0-1000 µg/m3
Detection limit < 0.05 µg/m3 (system)
Precision (accuracy) < 0.01 µg/m3 / 3 months
Max. drift < 0.15 µg/m3 / 3 months
Operating temperature +5°C to +40°C (without air conditioning)
Sample max temperature 200°C as standard (others as option)
Display Touch screen
Heated sampling line custom-made: from 2 to 60 m
Communication 4-20 mA, RS232, Modbus RTU/RS485, Modbus TCP/IP, TCP-IP
Power supply 230 V / 50 Hz or 110 V / 60Hz
Power consumption Analyzer cabinet: 1850W (total)
Sampling box: 800W
Probe controller: 600W (0,6m), 800W (1m) or 1200W (1,5m)
Heated line: 120W/m
Air instrument consumption 5-10 bar, max. 16 L/min (for backflush)
Mounting flange DN65 / PN6, other on request
Dimensions (H x L x W) cm Analyzer cabinet: 190.5x80x65
Sampling box: 26x34x34,5
Probe controller: 25x35x15 (27x38x18 incl. fixations)
Weight Analyzer cabinet: 224 kg
Sampling box: 15.4 kg
Stinger: 9 to 12 kg, depending on length
Probe controller: 10 kg
Protection Rating Analyzer cabinet IP55, Sampling IP54, Probe
controller IP66

FEATURES BENEFITS
Very low certification range High measurement accuracy
Instrument certified to operate without calibration Reliability & reduced operating costs
Simple and robust design Maximum availability, easy servicing with low maintenance costs
Converter oven without catalyst Requires no consumables, minimized operating costs
Very low instrument air consumption Lower operating costs
Customizable heated sampling line Remote installation for easy access to the analysis cabinet
Over 20 years of expertise in mercury analysis Guarantee of a high quality and high performance product

GOEDKEURINGEN & CERTIFICERINGEN
Naleving van de regelgeving:
  • QAL1-certificering door het laboratorium TÜV Rheinland Energie und Umwelt GmbH, volgens EN 14181, EN 15267-1, EN 15267-2, EN 15267-3 (Europese regelgeving); Download het TÜV-certificaat: 0000074628
  • Nieuwe BREF voor afvalverbranding
  • Richtlijn industriële emissies (IED) 2010/75/EU
  • Richtlijn grote stookinstallaties (LCPD) BREF
  • Richtlijn Integrated Pollution Prevention Control (IPPC)
  • Voldoet aan nationale en internationale wettelijke vereisten
  • Prestatiespecificatie 12A voor Mercury | US EPA 40 CFR-onderdelen 60 en 63
  • Nationale emissienormen voor gevaarlijke luchtverontreinigende stoffen (NESHAP) voor de productie-industrie van Portlandcement
  • Minamata-conventie & Europese richtlijnen voor thermische centrales, afvalverbrandingsinstallaties en grote stookinstallaties
Onze kwikanalysers zijn vervaardigd volgens de ISO 9001 kwaliteitsvoorschriften.

CE goedgekeurd

Documentatie

envea_catalogue_cems_emission-monitoring_en envea_catalogue_cems_emission-monitoring_en
envea_sm-5_mercury-cems-analyzer-emissions_en envea_sm-5_mercury-cems-analyzer-emissions_en
envea_sc-5000_option-sm-5_datasheet_system-check-mercury-analyzer_en envea_sc-5000_option-sm-5_datasheet_system-check-mercury-analyzer_en

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group