Meet Stof Merk: Envea Type meting: in-situ

Stofmeter QAL 181

QAL1-goedgekeurde ProScatter™-deeltjes-CEM die hoogwaardige emissiemetingen biedt van lage stofconcentraties uit droge industriële processen

QAL1 Forward Scatter Particulate CEM QAL 181
QAL1 Goedgekeurde ProScatter™ particulate CEM biedt hoogwaardige emissiemeting van lage stofconcentraties van droge industriële processen

4 QAL1 gecertificeerde bereiken, waaronder 0 – 7,5 mg/m3, het laagst haalbare voor elke PM-CEM

Kenmerken en voordelen

  • QAL1-certificeringsbereiken: 0 – 7,5 mg/m3, 0 – 15 mg/m3, 0 – 100 mg/m3, 0 – 200 mg/m3
  • Robuust ontwerp zonder kritische bewegende delen
  • Beschikbaar voor gebruik in hogetemperatuurstapelomstandigheden en Ex-gevaarlijke zones
  • Eenvoudig te monteren flens met meerdere patronen
  • Instelbare bewakingsdiepte om bemonstering in het meest representatieve deel van het stromingspad te garanderen
  • Verbeterde meting dankzij verminderde kruisgevoeligheid voor deeltjestype en -grootte
  • ProScatter™-technologie biedt verbeterde meting dankzij verminderde kruisgevoeligheid voor deeltjestype en -grootte
  • Eenvoudig te controleren met handmatige filters

Belangrijkste toepassingen

  • Deeltjesbewaking na zakfilters, patroonfilters, cyclonen, elektrostatische precipitators, geen filtratie
  • Niet-condenserende / droge rookgassen

Typische toepassingen:

  • Verbranding
  • Metalen (bijv. staal/aluminium)
  • Mineralen (bijv. cement/gips)
  • Chemicaliën (bijv. TiO2/raffinaderij)
  • Elektriciteitscentrale (bijv. steenkool/biomassa)

Technical Specifications
Measured parameters Dust
Technology ProScatter™ Forward Scatter
Measurement/Monitoring capability 0-1000 mg/m3*
Stack/Duct diameter suitability up to 8m
Flue gas temperature up to 500°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter YES
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
MCERTS & TÜV (UBA) to EN15267-3 YES
QAL1 certified to EN14181 YES
QAL3 to EN14181 YES
GOST YES
ATEX YES
Sensor variants Stainless Steel
Hastelloy® corrosion resistant
QA checks YES

*Application dependant

Technical data
Measurement capability 0 – 1000 mg/m3
QAL1 certification range 0 – 7.5 mg/m3
0 – 15 mg/m3
0 – 100 mg/m3
0 – 200 mg/m3
Resolution 0.01 mg/m3
Sensor Variants Stainless Steel (standard). Corrosion resistant Hastelloy (option)
Stack Temperature Ranges 0-250°C. Up to 500°C option
Functionality and QA Checks Automatic zero and upscale checks QA data logging
Data Output RS485 (Modbus) output to Controller
Air Purge requires continuous air purge
Enclosure Protection Rating IP66

Goedkeuringen en certificeringen

  • MCERTs and TÜV (UBA) certified to EN15267-3 (incl. 0-7.5 mg/m3)
  • QAL1 as defined by EN14181
  • QAL3 compliance to EN14181
  • EN13284
  • GOST Approved, etc.
  • Ex Zone 2

Documentatie

ENVEA_Process_Catalogue_EN ENVEA_Process_Catalogue_EN
envea_catalogue_cems_emission-monitoring_en envea_catalogue_cems_emission-monitoring_en
envea_technical-services-datasheet_en envea_technical-services-datasheet_en
envea_qal-181_qal1-light-scatter_particulate-cems-monitor_en envea_qal-181_qal1-light-scatter_particulate-cems-monitor_en

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group