Dutch          
Industrial Measurement & Control, CEM systems, measuring vans, shelter, analysers and gasconditiongcomponents
Laboratory equipment, color-, ph-, ion selective-, polari-, refracometers
Farmer measurements, NH3, emmision
Reduced Oxygen Reduced Breathing Device, Gas mixing systems
Refractometers, Color measurements and Calcium
Service, Preventive and corrective maintenance, 24/7 contracts
Marine emission monitoring
Home > Products > Callibration Systems > Mercury Calibrator MC-3000

Filter.

Component







































Show More


Type of measurement









Show More

Principal































Show More

Mercury Calibrator MC-3000

The MC-3000 is used for generating a continuous stream of a mercury vapor loaded gas stream in order to check or calibrate mercury analyzers. It is also suitable for all those applications where a gas stream with a preset and constant mercury concentration is needed. Generator of mercury calibration gas MC 3000

The MC-3000 generates a continuous stream of a mercury vapor loaded gas in order to check or calibrate mercury analyzers

An exactly adjustable carrier gas stream (normally air or nitrogen) is loaded with mercury in a first step.

In a second step the gas is supersaturated by cooling. Subsequently the excess mercury is condensed in a special cell to get exact saturation. The gas is then diluted, the dilution ratio is continuously adjustable in order to obtain concentrations within a specific range.

FEATURES & BENEFITS

  • Generates elemental mercury vapor
  • Continuous operation
  • Approx. 10 to 500 µg/m³ Hg°
  • Compact sized and portable
  • No permeation principle – no need to calibrate the calibrator
  • Microprocessor controlled


MAIN APPLICATIONS
Suitable for all applications where a gas stream with a preset and constant mercury concentration is needed

TECHNICAL SPECIFICATIONS
Range of concentrations approx. 10 to 500 µg / m³ Hg°
Generated calibration gas flow 1 to 9 l/min, depending on conc.
Carrier gas Air, Nitrogen
Carrier gas flow max. 12.5 l(min)
Carrier gas pressure 1 to 3 bar
Cleansing of carrier gas builtin particular filter (0.2 µm )
Mercury absorption filter sulphurized activated carbon at outlet
Temperature sensors Pt-100 with 0.01 °C accuracy
Flowmeter electronic mass flow controller (MFC)
Connectors for tubing 4mm i. d. / 6mm o. d.
TECHNICAL DATA
Power supply 230 VAC / 50 Hz (110 VAC / 60 Hz option)
Power consumption 30 VA
Dimensions (W x H x D) 45 x 18 x 27 cm
Weight approx. 5 kg

APPROVALS & CERTIFICATIONS

  • Our products are manufactured according to the ISO 9001 quality regulations.
  • CE approved

Documentation

MC_3000_generation_mercury_calibration_gas_EN_1019 MC_3000_generation_mercury_calibration_gas_EN_1019

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group