Water content determination Litronic WMS II

The Liebherr Litronic WMS II water content meter is used to measure the moisture or water content of a wide range of water content

Liebherr sensors in use in explosive areas

The Liebherr Litronic WMS II water content meter is used to measure the moisture or water content of a wide range of water content of a wide variety of media and materials in refineries, on oil platforms, in pipelines, in tanks, in many applications in the chemical and petrochemical industry, sludge dewatering, drying, waste incineration and sewage treatment plants. Also in the agricultural sector up to the pharmaceutical industry and many other industries.

The wide range of applications extends from the most diverse emulsions to the finest powders and dusts and coarse-grained materials (max. grain size 32 mm) such as

  • Oil, crude oil, diesel, biodiesel, hardening oil (upstream / downstream)
  • Coolants
  • Paints, lacquers, solvents
  • Wax, resin
  • Other emulsions, suspensions
  • Water-product separation
  • Dust, slag
  • Fertiliser
  • Washing powder, agent
  • Sawdust
  • Biomass
  • Flour
  • etc.

Applications:

  • Water cut meter
  • Pipeline, tanks BS&W (Basic sediment and water) measurement
  • Petroleum purification/desalination
  • Automatic well testing
  • LACT units
  • Separation control


The self-sufficient measuring device for precise water content/moisture determination in the running process guarantees the highest quality and safety in EX-protected production environments, the further processing and refinement of very many emulsions and bulk materials.

The PC software enables fast and accurate calibration of the measured sections.

Liebherr offers sensors for the following device protection categories:

Certificates
ATEX:
EU-type examination certificate number: EPS 21 ATEX 1 140 X
DIN EN IEC 60079-0:2018, 60079-1:2014, EN 60079-11:2012, EN 60079-26:2015, EN 60079-31:2014

Gas EX-protection:
II 1/2 G Ex db/ia IIC T4 Ga/Gb

Dust EX-protection:
II 1/2 D Ex tb/ia IIIC T135°C Da/Db

IECEx:
Certificate number: IECEx EPS 21.0047X
IEC 60079-0:2017 Edition: 7.0, IEC 60079-1:2014-06 Edition: 7.0,
IEC 60079-11:2011 Edition: 6.0, IEC 60079-26:2014-10 Edition: 3.0,
IEC 60079-31:2013 Edition: 2

Gas EX-protection:
Ex db/ia IIC T4 Ga/Gb

Dust EX-protection:
Ex tb/ia IIIC T135°C Da/Db

In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility.

Once the system has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.

Benefits:

  • Indirect measuring method: Capacity determination in the high frequency stray field. This method uses the different dielectric constant (permittivity) of water and different materials (solids and liquids)
  • Fully reproducible sensors: If the plant is subsequently extended with sensors or if sensors are replaced, no recalibration is necessary thanks to the built-in microprocessor.
  • Process control and regulation: Thanks to extensive interfaces, the moisture measurement can be integrated into process control systems and controls.
  • Cost saving: Time-consuming and costly laboratory analyses are no longer necessary or can be reduced.
  • Temperature measurement/temperature compensation: The sensor can also be used to determine the temperature of the medium.
  • Limit values: Maximum or minimum limits can be set using the software. Light or sound signals can be triggered if required.
  • Mean value calculator: The sensor passes on already averaged values to the FMS evaluation and transfer module.
  • Compressive strength: The rod sensor withstands process pressures of up to 100 bar.
  • Sliding fitting: For cleaning, flushing or sensor replacement, the sliding fitting can be easily pulled out of the pipeline even under these circumstances without disturbing the process.

Accessories:

  • Pressure sensor: The pressure sensor measures the pressure of the pipeline or tank system. (only on P45-GD rod sensor)
  • Flange: Use the flange to connect the sensor to the pipeline, tank system or bulk solid receptacle
  • Sliding fitting: With the sliding fitting you can mount the sensor on tank systems (rod sensor) and pipelines. The sliding fitting allows the sensor to be changed quickly without having to empty and depressurise the tank or the pipe.
  • External display and control unit: The display and control unit is mounted up to 50 m away from the sensor in an easily accessible position. It is connected directly to the electronics of the sensor and powered by it.
  • Software: for start-up and configuration.

Documentation

data-sheet-wms-ii-planar-sensor-p45-gd data-sheet-wms-ii-planar-sensor-p45-gd
data-sheet-wms-ii-planar-sensor-p78-gd data-sheet-wms-ii-planar-sensor-p78-gd
data-sheet-wms-ii-rod-sensor-p45-gd data-sheet-wms-ii-rod-sensor-p45-gd
brochure-litronic-wmsii-water-content-determination brochure-litronic-wmsii-water-content-determination
iecex_eps_21.0047_000_signed_scan iecex_eps_21.0047_000_signed_scan
lieb_20th0483_wms-sensor_eps-21-atex-1-140-x_en_0_signed_scan lieb_20th0483_wms-sensor_eps-21-atex-1-140-x_en_0_signed_scan

Liebherr data sensor P45-GD/P78-GD

- Evaluation of the complex dielectric in the high frequency stray field
- Freely scalable measuring range
- Material curve switching
- Sensor replacement without recalibration
- Temperature compensation  

Ankersmid Process