Dutch          
Industrial Measurement & Control, CEM systems, measuring vans, shelter, analysers and gasconditiongcomponents
Laboratory equipment, color-, ph-, ion selective-, polari-, refracometers
Farmer measurements, NH3, emmision
Reduced Oxygen Reduced Breathing Device, Gas mixing systems
Refractometers, Color measurements and Calcium
Service, Preventive and corrective maintenance, 24/7 contracts
Marine emission monitoring
Home > Products > In Situ gas analysers > Dust measurement > Electrodynamic Dust Monitor View 820

Filter.

Component







































Show More


Type of measurement









Show More

Principal































Show More

Measuring Dust Brand: Envea Type of measurement: In-situ

Electrodynamic Dust Monitor View 820

Certified Multi-sensor dust monitor – category 1 under ATEX / IECEx – for indicative emissions trending and measurement in hazardous zone and in dry processess with elevated pressures.

ELECTRODYNAMIC DUST MONITOR VIEW 820

Certified Multi-sensor dust monitor – category 1 under ATEX / IECEx – for indicative emissions trending and measurement in hazardous zone and in dry processess with elevated pressures.

Advanced Probe Electrification featuring long term data logging for process trend analysis and reporting.

FEATURES & BENEFITS

  • Reliable measurement of leaking and broken bags in dust collectors
  • Sensor configured remotly via controller
  • Automatic sensor drift checks (zero and span)
  • Automatic probe check (Insulator Short-Circuit Check) for improved data integrity
  • Reduces filter maintenance intervals, process down-time and filter costs

MAIN APPLICATIONS

  • Stacks after bag filters, cartridge filters, cyclones
  • Variable velocities within range 4-30m/s (typical bagfilter velocity ranges), constant velocity required outside this range
  • High Pressure applications
  • Explosive atmosphere zones 0, 1, 2, 20, 21 and 22

Typical Applications:

  • Minerals (eg Coal Gasification)
  • Petrochemicals (eg Plastics manufacture)
  • Power (eg Biomas)

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Measured parameters Dust
Technology ElectroDynamic® Advanced Probe Electrification
Measurement/Monitoring capability 0-500 mg/m³*
Stack/Duct diameter suitability up to 6m
Flue gas temperature up to 450°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter YES
Coalescent Filter /
Cyclone YES
Electrostatic Precipitator (ESP) /
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
QA checks N/A

*Application dependant


TECHNICAL DATA

TECHNICAL DATA
Monitoring capability 0-500 mg/m3
Sensor Variants 316 Stainless Steel (standard)
Stack Temperature Ranges 0-400°C (450°C option)
Pressure Rating < 50Bar (0-400°C) <38 Bar (0-450°C)
On-board data logging User configurable Long term, Short term or Pulse logging
Outputs RS232, RS485 (Modbus), Ethernet Digital Alarm and 4/20mA (number of outputs dependant on controller type)

APPROVALS & CERTIFICATIONS

  • Ex Zone 0, 1, 2
  • US EPA MACT Compliant BLD

Documentation

ENVEA_Process_Catalogue_EN (1) ENVEA_Process_Catalogue_EN (1)
envea_technical-services-datasheet_en envea_technical-services-datasheet_en
envea_rugged-sensor-options_en envea_rugged-sensor-options_en
envea_view-800-820_high-temp-pressure-particulate-measurement-monitors_en envea_view-800-820_high-temp-pressure-particulate-measurement-monitors_en

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group