Home > Products > In Situ gas analysers > Dust measurement > Dustmonitor STACK 181

Filter.

Component







































Show More


Type of measurement









Show More

Principal































Show More

Measuring Dust Brand: Envea Type of measurement: In-situ

Dustmonitor STACK 181

US EPA PS11 compliant ProScatter™ particulate CEM providing high quality emission measurement for low dust concentrations from industrial processes

PS11 Capable Forward Scatter Particulate CEM STACK 181
US EPA PS11 compliant ProScatter™ particulate CEM providing high quality emission measurement for low dust concentrations from industrial processes

Utilising the patented ProScatter™ Forward Scatter measurement technique for measuring particulate concentration levels, typically between 0.06 mg/m3 to 300 mg/m3, this measurement technique offers improved levels of performance which make the STACK 181 very suitable for use as a PM CPMS or PM CEMS that need to comply with US EPA PS-11 for Site Operators looking to satisfy the recent MACT and MATS rules.

The STACK 181 is suitable for measuring particle emissions after both bag filter and electrostatic precipitator arrestment plant.

Features & Benefits

  • Robust design with no critical moving parts
  • Available for use in high-temperature stack conditions and Ex hazardous zones
  • Easy to fit multi-patterned flange
  • Adjustable monitoring depth to ensure sampling in the most representative part of the flow path
  • For use as PM-CPMS or PM-CEMS that need to comply with PS-11
  • ProScatter™ technology offers enhanced measurement due to reduced cross-sensitivity of particle type and size
  • Features automatic zero and upscale checks that fully challenge the system’s ability to measure forward-scattered light and satisfy daily drift checks
  • Easily audited with manual filters

Main applications

  • Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration.
  • Non-condensing / dry flue gases
  • Incineration
  • Metals eg Steel/Aluminium
  • Minerals eg Cement/Gypsum
  • Chemicals eg TiO2 / Refinery
  • Power Generation Plant eg Coal/Biomass

Technical Specifications
Measured parameters Dust
Technology ProScatter™ Forward Scatter
Measurement/Monitoring capability 0-200 mg/m3*
Stack/Duct diameter suitability up to 8m
Flue gas temperature up to 500°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter YES
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
QA checks YES

Technical data
Measurement capability 0 – 1000 mg/m3
Certification Range 0 – 15 mg/m3
0 – 100 mg/m3
Resolution 0.01 mg/m3
Sensor Variants Stainless Steel (standard). Corrosion resistant Hastelloy (option)
Stack Temperature Ranges 0-250°C. Up to 500°C option
Functionality and QA Checks Automatic zero and upscale checks QA data logging
Data Output RS485 (Modbus) output to Controller
Air Purge requires continuous air purge
Enclosure Protection Rating IP66

Approvals & Certifications

  • US EPA PS-11 compliant
  • Ex Zone 2

Documentation

envea_technical-services-datasheet_en envea_technical-services-datasheet_en
envea_stack-181_ps11-capable-forward-scatter-particulate-cem_en envea_stack-181_ps11-capable-forward-scatter-particulate-cem_en
envea_catalogue_cems_emission-monitoring_en envea_catalogue_cems_emission-monitoring_en

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group