Dutch          
Industrial Measurement & Control, CEM systems, measuring vans, shelter, analysers and gasconditiongcomponents
Laboratory equipment, color-, ph-, ion selective-, polari-, refracometers
Farmer measurements, NH3, emmision
Reduced Oxygen Reduced Breathing Device, Gas mixing systems
Refractometers, Color measurements and Calcium
Service, Preventive and corrective maintenance, 24/7 contracts
Marine emission monitoring

Filter.

Component







































Show More


Type of measurement









Show More

Principal































Show More

Liebherr data sensor P45-GD/P78-GD

- Evaluation of the complex dielectric in the high frequency stray field
- Freely scalable measuring range 
- Material curve switching 
- Sensor replacement without recalibration 
- Temperature compensation Benefits:
  • Indirect measuring method: Capacity determination in the high frequency stray field. This method uses the different dielectric constant (permittivity) of water and different materials (solids and liquids)
  • Fully reproducible sensors: If the plant is subsequently extended with sensors or if sensors are replaced, no recalibration is necessary thanks to the built-in microprocessor.
  • Process control and regulation: Thanks to extensive interfaces, the moisture measurement can be integrated into process control systems and controls.
  • Cost saving: Time-consuming and costly laboratory analyses are no longer necessary or can be reduced.
  • Temperature measurement/temperature compensation: The sensor can also be used to determine the temperature of the medium.
  • Limit values: Maximum or minimum limits can be set using the software. Light or sound signals can be triggered if required.
  • Mean value calculator: The sensor passes on already averaged values to the FMS evaluation and transfer module.
  • Compressive strength: The rod sensor withstands process pressures of up to 100 bar.
  • Sliding fitting: For cleaning, flushing or sensor replacement, the sliding fitting can be easily pulled out of the pipeline even under these circumstances without disturbing the process.

Accessories:

  • Pressure sensor: The pressure sensor measures the pressure of the pipeline or tank system. (only on P45-GD rod sensor)
  • Flange: Use the flange to connect the sensor to the pipeline, tank system or bulk solid receptacle
  • Sliding fitting: With the sliding fitting you can mount the sensor on tank systems (rod sensor) and pipelines. The sliding fitting allows the sensor to be changed quickly without having to empty and depressurise the tank or the pipe.
  • External display and control unit: The display and control unit is mounted up to 50 m away from the sensor in an easily accessible position. It is connected directly to the electronics of the sensor and powered by it.
  • Software: for start-up and configuration.

Technical data planarsensor P45-GD

Suitable for use in potentially explosive areas Dust/Gas - Zone 0/20
Measurement  
Physical principle Capacity determination in the high frequency stray field
Measurement location Pipeline, Tank
Adjustable measuring range 0 - 100 % moisture content (measuring window adjustable)
Number of scattered fields 1
Update cycle 65 ms
Achievable measurement accuracy ± 0.05 % with correct material curve
Temperature measurement accuracy ± 0.5 °C
Outflow  
Measured value transmission - Sensor display content Current loop with “4 - 20 mA” for external display (option)
Measured value transmission - sensor PLC or main computer Analogue: “4 - 20 mA” active at 500 Ohm digital: Hart Modem
Valid measurement 3.75 mA to 21.6 mA (NAMUR)
Interface signal resolution 16 bit
Max. length of connecting cable 1000 m (depending on cable)
Power supply  
Connection 24 V, 150 mA DC
Temperature  
Medium temperature -5 °C* to 80 °C (Standard)
Ambient temperature sensor head 5 °C to 80 °C
Ambient temperature transmitter head 5 °C to 70 °C
Storage temperature -25 °C to 80 °C
* Under certain conditions  
Pressure  
Pressure -1 bar up to 100 bar
Pressure measurement (optional) relative up to 40 bar
Material  
Housing / rod material 1.4571 (optional 2.4819)
Transmitter head material Aluminium
Measuring field material/wearing protection PEEK
Dimensions  
Housing W/H/D 88 mm
160 mm
143 mm
Rod diameter 45 mm
Rod length 6" to 32" (further lengths on request)
Measuring field material PEEK
Measuring field position Front or side


Technical data planarsensor P78-GD:
Suitable for use in potentially explosive areas Dust/Gas - Zone 0/20
Measurement  
Physical principle Capacity determination in the high frequency stray field
Measurement location Chutes, belts, silo outlets, tanks, etc.
Adjustable measuring range 0 - 100 % moisture content (measuring window adjustable)
Number of scattered fields 1
Achievable measurement accuracy ± 0.05 % with correct material curve
Temperature measurement accuracy ± 0.5 °C
Outflow  
Measured value transmission - Sensor display content Current loop with 4 - 20 mA for external display (option)
Measured value transmission - sensor PLC or main computer Analogue: 4 - 20 mA active at 500 Ohm digital: Hart Modem, Modbus RTU
Valid measurement 3.75 mA to 21.6 mA (NAMUR)
Interface signal resolution 16 bit
Max. length of connecting cable 1000 m (depending on cable)
Power supply  
Connection 24 V, 150 mA DC
Temperature  
Medium temperature -5 °C* to 80 °C (Standard)
Ambient temperature sensor head 5 °C to 80 °C
Ambient temperature transmitter head 5 °C to 70 °C
Storage temperature -25 °C to 80 °C
* Under certain conditions  
Pressure  
Pressure Flange for bolting on: -1 bar to 1 bar
Flange for welding on: -1 bar to 16 bar
Material  
Housing material 1.4571 (optional 2.4819)
Measuring field material/wearing protection Ceramic, ZrO2
Dimensions  
Sensor 78 mm
Housing transmitter head W/H/D 88 mm
160 mm
143 mm
Cable length between sensor and transmitter head 10 m

Documentation

data-sheet-wms-ii-planar-sensor-p78-gd data-sheet-wms-ii-planar-sensor-p78-gd
data-sheet-wms-ii-rod-sensor-p45-gd data-sheet-wms-ii-rod-sensor-p45-gd
brochure-litronic-wmsii-water-content-determination brochure-litronic-wmsii-water-content-determination
iecex_eps_21.0047_000_signed_scan iecex_eps_21.0047_000_signed_scan
lieb_20th0483_wms-sensor_eps-21-atex-1-140-x_en_0_signed_scan lieb_20th0483_wms-sensor_eps-21-atex-1-140-x_en_0_signed_scan
data-sheet-wms-ii-planar-sensor-p45-gd data-sheet-wms-ii-planar-sensor-p45-gd

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group