Dutch          
Industrial Measurement & Control, CEM systems, measuring vans, shelter, analysers and gasconditiongcomponents
Laboratory equipment, color-, ph-, ion selective-, polari-, refracometers
Farmer measurements, NH3, emmision
Reduced Oxygen Reduced Breathing Device, Gas mixing systems
Refractometers, Color measurements and Calcium
Service, Preventive and corrective maintenance, 24/7 contracts
Marine emission monitoring

Filter.

Component







































Show More


Type of measurement









Show More

Principal































Show More

Measuring Dust Brand: Envea Type of measurement: In-situ

Dustmonitor QAL 260

MCERTS QAL1 approved, stand alone or multi-sensor Particulate CEM providing high quality emission measurement for low dust concentrations from dry industrial processesMCERTS QAL1 approved, stand alone or multi-sensor Particulate CEM providing high quality emission measurement for low dust concentrations from dry industrial processes.

MCERTS Approved Back Scatter Particulate CEM

Kenmerken en voordelen

  • ProScatter™ Backscatter sensor technology with superior minimum detection <1mg/m3
  • Certified to 15 mg/m3 for processes with low typical emission limits
  • Manual and remote Zero and Span (reference) checks available to ensure optimal instrument performance and to comply with EN 13284/QAL1
  • Automatic Functionality Check – fully interrogates the optical system
  • Purge Flow Fail Sensor option with inbuilt automatic optical shield activation
  • Flue Gas Blocker option to protect Plant Engineers from harmful flue gases during maintenance

Belangrijkste toepassingen

  • Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
  • Non-condensing / dry flue gases
  • Typical Applications:
  • Incineration
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg TiO2 / Coating Powder)
  • Power Generation Plant (eg Coal/Biomass)

Technical Specifications
Measured parameters Dust
Technology ProScatter™ Backscatter
Measurement/Monitoring capability <0 – 500 mg/m3*
Stack/Duct diameter suitability up to 10m
Flue gas temperature up to 400°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter /
Coalescent Filter /
Cyclone YES
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
QA checks YES

*Application dependant

Technical data
Measurement capability <0 – 500 mg/m3
Sensor Variants 316 Stainless Steel
Stack Temperature Ranges -20°C – 250°C up to 400°C option
Functionality and QA Checks Automatic zero and span
Data Output RS485 (Modbus) output to Controller
Air Purge option
Enclosure Protection Rating IP65

Goedkeuringen en certificeringen

  • MCERTs certified to EN15267-3
  • QAL1 as defined by EN14181
  • QAL3 compliance to EN14181

Documentation

envea_technical-services-datasheet_en envea_technical-services-datasheet_en
envea_qal-260_qal1-back-scatter-particulate-emission-monitor_en envea_qal-260_qal1-back-scatter-particulate-emission-monitor_en
ENVEA_Process_Catalogue_EN ENVEA_Process_Catalogue_EN
envea_catalogue_cems_emission-monitoring_en envea_catalogue_cems_emission-monitoring_en
envea_qal-260_datasheet_qal1-back-scatter-particulate-emission-monitor_en envea_qal-260_datasheet_qal1-back-scatter-particulate-emission-monitor_en

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group